 782482 Series
ADM2482E/ADM2487E Compatible Converter Transformers
SELECTION GUIDE
Order Code
782482/33VC 782482/53VC
Nominal Input Voltage V
3.3 5.0
Nominal Output Voltage V
3.3 3.3
Isolation Voltage VDC
4000 4000
Turns Ratio
1CT:1.33CT 1.14CT:1CT
Package Style
DIL DIL
CHARACTERISTICS
Parameter Conditions
1 P 1 L
782482/33VC
Min. 190 Max. 310 8 8 600
782482/53VC
Min. 150 Max. 260 8 8 600
Units
H H pF m Vs
FEATURES
RoHS compliant Analog Devices ADM2482E/ADM2487E compatible 4.0kVDC isolation Industry-standard pinout UL 94 V-0 package materials Low profile Toroidal construction Fully encapsulated Industrial temperature range Surface mount versions available soon Recommended by Analog Devices, Inc. Backward compatible with Sn/Pb soldering systems
Primary Inductance, L Leakage Inductance, L Interwinding Capacitance, CWW Primary DC Resistance, RDC1 Volt-time Product, Et2
100kHz, 20mV 100kHz, 250mV 100kHz, 250mV <0.1VDC 5kHz, 5V
13
13
ABSOLUTE MAXIMUM RATINGS
Operating free air temperature range Storage temperature range Isolation voltage (flash tested for 1 second)
-40C to 85C -50C to 125C 4.0kVDC
SOLDERING INFORMATION3
Peak wave solder temperature Pin finish
Specifications typical at TA = 25C 1 LP, LL and RDC measured between pins 1-3. 2 Where pulse applied across pins 1 and 2. 3 For further information, please visit www.murata-ps.com/rohs
260C for 10 seconds Matte tin
TECHNICAL NOTES
ISOLATION VOLTAGE REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. This series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements.
DESCRIPTION
The 782482 series of converter transformers are specifically designed for use with Analog Devices chipsets to provide isolated RS-485 and RS-422 interfaces. Carefully controlled turns ratios ensure consistent performance whilst a toroidal construction minimises EMI.
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KMP_782482C_A01 Page 1 of 2
782482 Series
ADM2482E/ADM2487E Compatible Converter Transformers
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
9.77 (0.385) Max.
RECOMMENDED FOOTPRINT DETAILS
TOP VIEW
Primary
Secondary
2.54 (0.10)
6
1
9.14 (0.360) Max.
2.54 (0.10)
2 5 4
782482/33VC
XYYWW
3
O1.20 (0.05) +0.15 (0.006) -0.00 (0.000)
6.35 (0.25)
3.440.50 (0.1350.02) 0.30(0.012) 0.20(0.008) 0.6 (0.024) 10.160.40 (0.400.016) 2.54 (0.1)
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position. Package Weight 1.1g TYP.
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54(0.1) pitch and within 0.25(0.01) of true position.
TUBE OUTLINE DIMENSIONS
10.65 - 11.65 (0.419 - 0.459) 4.00 (0.16) 0.600.15 (0.0240.006) 12.95 (0.51)
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). Tube length: 5002 (19.70.08) Tube quantity: 50 Tube material: Antistatic coated clear PVC.
5.20 (0.21) 3.80 (0.15) 15.70 (0.62)
USA: UK: France: Japan:
Mansfield (MA), Tel: (800) 233 2765, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
Germany: Munchen, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
China:
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KMP_782482C_A01 Page 2 of 2


▲Up To Search▲   

 
Price & Availability of 782482

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X